Guides
6 min readUpdated
A paired entrance needs a decision about each leaf. Define one-leaf or two-leaf powered passage, then assess support, meeting edges, closing and connected controls together.
At a glance
- Decide whether one leaf or both should open under power.
- Meeting details and closing order affect the proposed arrangement.
- Record activation, release, movement and final securing for each input.
Decide what each leaf should do before choosing an operator
Adding power to a pair of commercial doors requires a decision about whether one leaf or both leaves should open under power, and how they operate together. The meeting edges, support, closing hardware, activation and locking must suit that intended movement. An operator on the everyday leaf and powered operation of both leaves are different proposals, even when they serve the same entrance.
Start by describing the passage people need during ordinary use. Then identify any separate need to open both leaves for deliveries or equipment. Having two leaves available does not mean that both will respond to a button, or that the combined opening describes the passage available during powered use.
Identify the pair and the role of each leaf
A pair has two leaves beside each other within an opening. A vestibule has separate openings along the route, such as outer and inner doors. A vestibule can itself contain pairs. Use an opening name and identify each leaf from a stated viewpoint so that a request concerning the left door cannot be mistaken for the inner door.
Have the assessor identify each leaf's role in the actual hardware arrangement. The dormakaba ED100/ED250 surface-applied installation instructions, Chapter 23, describe both active and inactive door operators. Inactive therefore does not universally mean incapable of powered movement.
Record any existing centre post, overlapping meeting detail or second-leaf securing hardware. Leave concealed details for the technician. A photograph from each accessible side can show the arrangement without removing hardware or moving an unstable leaf.
Separate three requests that can sound like the same installation
Use these descriptions to make the intended result clear before equipment is selected:
- Everyday powered passage through one leaf. Name the leaf that should respond and describe what the other leaf should do during that cycle.
- Powered everyday passage with occasional wider access. Explain when both leaves are needed and whether the second leaf is intended to be opened manually. That additional use still needs an assessed operating and securing arrangement.
- Powered passage through both leaves. State which activation points should request both leaves and have the opening and closing order confirmed for the selected assembly.
These are planning requests, not confirmation that every existing pair can support each option. If the purpose is easier access for visitors, establish the usable passage with the intended leaf or leaves open. The commercial door measurement guide explains why leaf size and clear passage are different. Do not assume that adding the two panel widths establishes the route available to a person using the activation control.
Meeting edges can change what opening together means
Some pairs have an astragal or another overlapping detail where the leaves meet. For its ED100/ED250 system, dormakaba distinguishes active-first opening for an astragal pair from simultaneous opening without an astragal. Treat that as a model-specific example of why meeting details affect selection. It is not approval of an existing overlap or a setting to copy to another operator.
Closing order is a separate question. Allegion's explanation of door coordinators describes devices that hold the active door open until the inactive leaf closes. Where a coordinator is present or proposed, ask how its function will work with the powered arrangement. Two leaves reaching their open positions does not demonstrate that they can return and latch in the required order.
Assess support and closing across the complete pair
Have the technician assess each moving leaf, its hinges or pivots, the frame and the proposed attachment areas. The selected operator's application instructions need to match the actual leaf size, construction, mounting space and arm arrangement. One long housing above a pair does not identify the equipment inside it. The dormakaba manual illustrates two operators within a double header.
Ask which closing components remain and how each leaf will return after powered or ordinary manual use. Keep that answer tied to the proposed system. A dragging leaf, loose support or meeting edges that catch need assessment before the operator arrangement is agreed. If an existing powered pair is struggling, request automatic door repair with a description of which leaf and stage are affected.
Write one labelled sequence for activation, release and movement
The following is an original planning outline for a proposed powered pair. It describes the decisions to put in the scope, not wiring, timing values or instructions to change controls:
- Request. Identify the outside plate, inside control or other input, and whether it requests one leaf or both.
- Release. Identify any connected locking that must release for the requested movement, and who is responsible for that function.
- Opening. Name the leaf or leaves that move and any required order at the meeting edges.
- Passage. Describe the intended route while open and identify the protective functions included in the selected system.
- Return. State how the leaves close and whether their closing order must be coordinated.
- Securing. Identify the intended final latch and locking state for each leaf in that operating mode.
LCN's 4630/4640 installation instructions illustrate simultaneous pair connections separately from vestibule arrangements. They also describe electric-lock release before powered opening. These examples support considering the input, movement and connected hardware together; they do not identify the system installed at your property.
Use a separate sequence where authorized entry outside public hours is intended to work differently. A reader admitting an authorized person and an inside control requesting exit should not be described only as buttons that open the doors. The proposal needs to identify the requested result from each input without changing or bypassing exit, locking or protective functions.
Compare the proposal with the requested passage
Read the proposed equipment against the leaf-by-leaf description. If the request calls for both leaves to move under power but the proposal only explains movement of one, resolve that gap. If the second leaf remains manual, ask how that affects the intended everyday route and occasional wider use. If another provider handles locking, make sure their work has an identified place in the sequence.
For power door operator installation, provide the whole pair, known equipment information and the intended use from each side. Identify an existing fire-door label or exit role for project review. Broader approach and project questions are covered in the automatic door accessibility planning guide. The paired-leaf decision should be settled alongside those requirements before the equipment order is finalized.
Questions about powering a commercial door pair
Do both leaves always need an operator?
The presence of two leaves does not decide that. Establish which leaves must move under power for the intended passage, then assess whether the existing assembly can support that arrangement. A one-leaf proposal should explain the second leaf's retained role.
Can one activation control request both leaves?
Supported paired systems can provide that function, as LCN's simultaneous-pair example shows. The control's appearance does not confirm the connection or operation. Ask the proposal to name which leaves each input will request.
Does fitting two operators automatically coordinate the pair?
No. Dormakaba's instructions include commissioning each leaf and communication between operators. Ask how the proposed equipment will be commissioned and checked as a pair.
What should a demonstration establish for this particular decision?
Ask for the agreed inputs, requested leaf movement, relevant release functions, closing order and final securing state to be checked against the written sequence. The useful result is confirmation of the intended paired passage, with any unfinished dependency clearly identified.